These motors have spool valve. The distributor valve has been integrated with the output shaft. The Gerotor set have plain teeth. These types of motors are suitable for long operating periods at moderate pressures or short operating periods at high pressures.
| MP | |||||||||||
| MP | Displacement | Max. speed | Max. Torgue | Max. Output | Max. Pressure Drop | Max. Oil Flow | |||||
| [cm3/rev] | [RPM] | [daNm] | [kW] | [bar] | [Ipm] | ||||||
| cont. | int* | cont. | int* | cont. | int* | cont. | int* | cont. | int* | ||
| MP 25 | 25 | 1600 | 1815 | 3,3 | 4,7 | 4,5 | 6,1 | 100 | 140 | 40 | 45 |
| MP 32 | 32 | 1560 | 1720 | 4,3 | 6,1 | 5,8 | 7,8 | 100 | 140 | 50 | 50 |
| MP 40 | 40 | 1500 | 1750 | 6,2 | 8,2 | 8,4 | 11,6 | 120 | 155 | 60 | 70 |
| MP 50 | 49,5 | 1210 | 1515 | 9,4 | 11,9 | 10,1 | 12,2 | 140 | 175 | 60 | 75 |
| MP 80 | 79,2 | 755 | 945 | 15,1 | 19,5 | 10,2 | 12,5 | 140 | 175 | 60 | 75 |
| MP 100 | 99 | 605 | 755 | 19,3 | 23,7 | 10,5 | 12,8 | 140 | 175 | 60 | 75 |
| MP 125 | 123,8 | 486 | 605 | 23,7 | 29,8 | 10,2 | 12 | 140 | 175 | 60 | 75 |
| MP 160 | 158,4 | 378 | 472 | 31,3 | 37,8 | 10,1 | 12,1 | 140 | 175 | 60 | 75 |
| MP 200 | 198 | 303 | 378 | 36,6 | 45,6 | 10 | 12 | 140 | 175 | 60 | 75 |
| MP 250 | 247,5 | 242 | 303 | 38 | 58,3 | 7,5 | 12 | 110 | 175 | 60 | 75 |
| MP 315 | 316,8 | 190 | 236 | 38 | 56 | 5,8 | 9 | 90 | 140 | 60 | 75 |
| MP 400 | 396 | 150 | 189 | 36 | 59 | 4,6 | 7,8 | 70 | 115 | 60 | 75 |
| MP 500 | 495 | 120 | 150 | 39 | 57 | 3,5 | 7,2 | 90 | 115 | 60 | 75 |
| MP 630 | 623,6 | 95 | 120 | 44 | 64 | 3,3 | 5,6 | 55 | 80 | 60 | 75 |
* Intermitten operation: the permissible values may occur for max. 10% of every minute
| Working conditions | |
| Pressure fluid | Mineral based-HLP(DIN 51524) or HM(ISO 6743/4) |
| Temperature range °C | 40 – 140 |
| Optimal Viscosity range (mm2/s ) | 20 – 75 |
| Filtration | ISO code 20/16 (Min. recommended fluid filtration of 25 micron ) |
These motors have spool valve. The distributor valve has been integrated with the output shaft. The Gerotor set have plain teeth. These types of motors are suitable for long operating periods at moderate pressures or short operating periods at high pressures.
| MM | |||||||||||
| MM | Displacement | Max. speed | Max. Torgue | Max. Output | Max. Pressure Drop | Max. Oil Flow | |||||
| [cm3/rev] | [RPM] | [daNm] | [kW] | [bar] | [Ipm] | ||||||
| cont. | int* | cont. | int* | cont. | int* | cont. | int* | cont. | int* | ||
| MM 8 | 8,2 | 1950 | 2440 | 1,1 | 2,1 | 1,8 | 2,6 | 140 | 200 | 16 | 20 |
| MM 12,5 | 12,9 | 1550 | 1940 | 1,6 | 2,3 | 2,4 | 3,2 | 140 | 200 | 20 | 25 |
| MM 20 | 20 | 1000 | 1250 | 2,5 | 3,5 | 2,4 | 3,2 | 140 | 200 | 20 | 25 |
| MM 32 | 31,8 | 630 | 790 | 4 | 5,7 | 2,4 | 3,2 | 140 | 200 | 20 | 25 |
| MM 40 | 40 | 500 | 625 | 4,1 | 5,7 | 1,8 | 3 | 110 | 140 | 20 | 25 |
| MM 50 | 50 | 400 | 500 | 4,5 | 5,8 | 1,7 | 2,1 | 90 | 125 | 20 | 25 |
* Intermitten operation: the permissible values may occur for max. 10% of every minute
| Working conditions | |
| Pressure fluid | Mineral based-HLP(DIN 51524) or HM(ISO 6743/4) |
| Temperature range °C | 40 – 140 |
| Optimal Viscosity range (mm2/s ) | 20 – 75 |
| Filtration | ISO code 20/16 (Min. recommended fluid filtration of 25 micron ) |
These motors have disc valve. The distributor valve has been separated from the output shaft and is driven by short cardan shaft. A balance plate counterbalances the hydraulic forces around the distributor valve. It gives the motor high efficiency even at high pressures and good starting characterstics. The Gerotor set have teeth fitted with rollers. The rollers reduce local stress and the tangential reaction forces on the rotor reducing friction to a minimum. This gives long operating life and better efficiency even at continuous high pressures.
| MT | |||||||||||
| MT | Displacement | Max. speed | Max. Torgue | Max. Output | Max. Pressure Drop | Max. Oil Flow | |||||
| [cm3/rev] | [RPM] | [daNm] | [kW] | [bar] | [Ipm] | ||||||
| cont. | int* | cont. | int* | cont. | int* | cont. | int* | cont. | int* | ||
| MT 160 | 161,1 | 622 | 775 | 47 | 56 | 26,5 | 32 | 200 | 240 | 100 | 125 |
| MT 200 | 201,4 | 620 | 752 | 59 | 71 | 33,5 | 40 | 200 | 240 | 125 | 150 |
| MT 250 | 251,8 | 496 | 601 | 73 | 88 | 33,5 | 40 | 200 | 240 | 125 | 150 |
| MT 315 | 326,3 | 382 | 461 | 95 | 114 | 33,5 | 40 | 200 | 240 | 125 | 150 |
| MT 400 | 410,9 | 304 | 368 | 108 | 126 | 30 | 35 | 180 | 210 | 125 | 150 |
| MT 500 | 523,6 | 238 | 289 | 122 | 137 | 26,5 | 30 | 160 | 180 | 125 | 150 |
| MT 630 | 631,5 | 197 | 234 | 130 | 148 | 24,3 | 27,5 | 140 | 160 | 125 | 150 |
| MT 725 | 724,3 | 172 | 209 | 127 | 147 | 20,2 | 26,8 | 120 | 140 | 125 | 150 |
* Intermitten operation: the permissible values may occur for max. 10% of every minute
| Working conditions | |
| Pressure fluid | Mineral based-HLP(DIN 51524) or HM(ISO 6743/4) |
| Temperature range °C | 40 – 140 |
| Optimal Viscosity range (mm2/s ) | 20 – 75 |
| Filtration | ISO code 20/16 (Min. recommended fluid filtration of 25 micron ) |
These motors have disc valve. The distributor valve has been separated from the output shaft and is driven by short cardan shaft. A balance plate counterbalances the hydraulic forces around the distributor valve. It gives the motor high efficiency even at high pressures and good starting characterstics. The Gerotor set have teeth fitted with rollers. The rollers reduce local stress and the tangential reaction forces on the rotor reducing friction to a minimum. This gives long operating life and better efficiency even at continuous high pressures.
| MS | |||||||||||
| MS | Displacement | Max. speed | Max. Torgue | Max. Output | Max. Pressure Drop | Max. Oil Flow | |||||
| [cm3/rev][cm3/rev] | [RPM] | [daNm] | [kW] | [bar] | [Ipm] | ||||||
| cont. | int* | cont. | int* | cont. | int* | cont. | int* | cont. | int* | ||
| MS 80 | 80,5 | 810 | 1000 | 24 | 31 | 15,5 | 19,5 | 210 | 275 | 65 | 80 |
| MS 100 | 100 | 750 | 900 | 30,5 | 39 | 18 | 22,8 | 210 | 275 | 75 | 90 |
| MS 125 | 125,7 | 600 | 720 | 37,5 | 49 | 18 | 22,5 | 210 | 275 | 75 | 90 |
| MS 160 | 159,7 | 470 | 560 | 49 | 60 | 16,5 | 23 | 210 | 275 | 75 | 90 |
| MS 200 | 200 | 375 | 450 | 61 | 72 | 16,5 | 22 | 210 | 275 | 75 | 90 |
| MS 250 | 250 | 300 | 360 | 72 | 87 | 14,5 | 18 | 200 | 250 | 75 | 90 |
| MS 315 | 314,5 | 240 | 290 | 82,5 | 100 | 15,7 | 17 | 200 | 240 | 75 | 90 |
| MS 400 | 397 | 190 | 230 | 86,5 | 99 | 11 | 12,5 | 160 | 190 | 75 | 90 |
| MS 475 | 474,6 | 160 | 190 | 85 | 99 | 8,4 | 11,3 | 130 | 150 | 75 | 90 |
| MS 525 | 522,7 | 145 | 175 | 85 | 99 | 7,6 | 10,4 | 115 | 135 | 75 | 90 |
| MS 565 | 564,9 | 130 | 160 | 85 | 99 | 6,9 | 9,6 | 105 | 125 | 75 | 90 |
* Intermitten operation: the permissible values may occur for max. 10% of every minute
| Working conditions | |
| Pressure fluid | Mineral based-HLP(DIN 51524) or HM(ISO 6743/4) |
| Temperature range °C | 40 – 140 |
| Optimal Viscosity range (mm2/s ) | 20 – 75 |
| Filtration | ISO code 20/16 (Min. recommended fluid filtration of 25 micron ) |
These motors have spool valve. The distributor valve has been integrated with the output shaft. The Gerotor set have teeth fitted with rollers. The rollers reduce local stress and the tangential reaction forces on the rotor reducing friction to a minimum. This gives long operating life and better efficiency even at continuous high pressures.
| MR | |||||||||||
| MR | Displacement | Max. speed | Max. Torgue | Max. Output | Max. Pressure Drop | Max. Oil Flow | |||||
| [cm3/rev] | [RPM] | [daNm] | [kW] | [bar] | [Ipm] | ||||||
| cont. | int* | cont. | int* | cont. | int* | cont. | int* | cont. | int* | ||
| MR 50 | 51,5 | 775 | 970 | 10 | 13 | 7 | 8,5 | 140 | 175 | 40 | 50 |
| MR 80 | 80,3 | 750 | 940 | 20 | 22 | 12,5 | 15 | 175 | 200 | 60 | 75 |
| MR 100 | 99,8 | 600 | 750 | 24 | 28 | 13 | 15 | 175 | 200 | 60 | 75 |
| MR 125 | 125,7 | 475 | 600 | 30 | 34 | 12,5 | 14,5 | 175 | 200 | 60 | 75 |
| MR 160 | 159,6 | 375 | 470 | 39 | 43 | 11,5 | 14 | 175 | 200 | 60 | 75 |
| MR 200 | 199,8 | 300 | 375 | 38,5 | 46 | 9 | 12 | 140 | 175 | 60 | 75 |
| MR 250 | 250,1 | 240 | 300 | 39 | 47 | 8 | 9,5 | 110 | 140 | 60 | 75 |
| MR 315 | 315,7 | 190 | 240 | 36 | 47 | 5 | 8 | 85 | 115 | 60 | 75 |
| MR 400 | 397 | 150 | 190 | 38 | 47 | 4,8 | 6,8 | 65 | 90 | 60 | 75 |
* Intermitten operation: the permissible values may occur for max. 10% of every minute
| Working conditions | |
| Pressure fluid | Mineral based-HLP(DIN 51524) or HM(ISO 6743/4) |
| Temperature range °C | 40 – 140 |
| Optimal Viscosity range (mm2/s ) | 20 – 75 |
| Filtration | ISO code 20/16 (Min. recommended fluid filtration of 25 micron ) |