• HOME
  • Pressure Control

Pressure Control

A Series

Hydro-Electric Pressure Switch

Pressure Reducing Valve

Unloading Relief Valve

H & HC Type Pressure Control Valve

4WE

These motors have spool valve. The distributor valve has been integrated with the output shaft. The Gerotor set have plain teeth. These types of motors are suitable for long operating periods at moderate pressures or short operating periods at high pressures.

Options

  • Flange and Wheel mount.
  • Motor with needle bearing.
  • Side or Rear ports.
  • Shafts: Straight, Splined or Tapered.
  • Shaft seal for high and low pressure
  • Ports: Metric or BSPP.
  • Speed sensoring.
  • Other special features.

Parameters

MP
MP Displacement Max. speed Max. Torgue Max. Output Max. Pressure Drop Max. Oil Flow
[cm3/rev] [RPM] [daNm] [kW] [bar] [Ipm]
cont. int* cont. int* cont. int* cont. int* cont. int*
MP 25 25 1600 1815 3,3 4,7 4,5 6,1 100 140 40 45
MP 32 32 1560 1720 4,3 6,1 5,8 7,8 100 140 50 50
MP 40 40 1500 1750 6,2 8,2 8,4 11,6 120 155 60 70
MP 50 49,5 1210 1515 9,4 11,9 10,1 12,2 140 175 60 75
MP 80 79,2 755 945 15,1 19,5 10,2 12,5 140 175 60 75
MP 100 99 605 755 19,3 23,7 10,5 12,8 140 175 60 75
MP 125 123,8 486 605 23,7 29,8 10,2 12 140 175 60 75
MP 160 158,4 378 472 31,3 37,8 10,1 12,1 140 175 60 75
MP 200 198 303 378 36,6 45,6 10 12 140 175 60 75
MP 250 247,5 242 303 38 58,3 7,5 12 110 175 60 75
MP 315 316,8 190 236 38 56 5,8 9 90 140 60 75
MP 400 396 150 189 36 59 4,6 7,8 70 115 60 75
MP 500 495 120 150 39 57 3,5 7,2 90 115 60 75
MP 630 623,6 95 120 44 64 3,3 5,6 55 80 60 75

 

* Intermitten operation: the permissible values may occur for max. 10% of every minute

Working conditions
Pressure fluid Mineral based-HLP(DIN 51524) or HM(ISO 6743/4)
Temperature range °C 40 – 140
Optimal Viscosity range (mm2/s ) 20 – 75
Filtration ISO code 20/16 (Min. recommended fluid filtration of 25 micron )

These motors have spool valve. The distributor valve has been integrated with the output shaft. The Gerotor set have plain teeth. These types of motors are suitable for long operating periods at moderate pressures or short operating periods at high pressures.

Options

  • With or Without flange.
  • Side or Rear ports.
  • Series with pressure valve(s).
  • Shafts: Straight or Splined.
  • Ports: Metric or BSPP
  • Speed sensoring.
  • Other special features.

Parameters

MM
MM Displacement Max. speed Max. Torgue Max. Output Max. Pressure Drop Max. Oil Flow
[cm3/rev] [RPM] [daNm] [kW] [bar] [Ipm]
cont. int* cont. int* cont. int* cont. int* cont. int*
MM 8 8,2 1950 2440 1,1 2,1 1,8 2,6 140 200 16 20
MM 12,5 12,9 1550 1940 1,6 2,3 2,4 3,2 140 200 20 25
MM 20 20 1000 1250 2,5 3,5 2,4 3,2 140 200 20 25
MM 32 31,8 630 790 4 5,7 2,4 3,2 140 200 20 25
MM 40 40 500 625 4,1 5,7 1,8 3 110 140 20 25
MM 50 50 400 500 4,5 5,8 1,7 2,1 90 125 20 25

 

* Intermitten operation: the permissible values may occur for max. 10% of every minute

Working conditions
Pressure fluid Mineral based-HLP(DIN 51524) or HM(ISO 6743/4)
Temperature range °C 40 – 140
Optimal Viscosity range (mm2/s ) 20 – 75
Filtration ISO code 20/16 (Min. recommended fluid filtration of 25 micron )

These motors have disc valve. The distributor valve has been separated from the output shaft and is driven by short cardan shaft. A balance plate counterbalances the hydraulic forces around the distributor valve. It gives the motor high efficiency even at high pressures and good starting characterstics. The Gerotor set have teeth fitted with rollers. The rollers reduce local stress and the tangential reaction forces on the rotor reducing friction to a minimum. This gives long operating life and better efficiency even at continuous high pressures.

Options

  • Flange and Wheel mount.
  • Short motor.
  • Motor with Drum Brake.
  • Tacho connection.
  • Speed sensoring
  • Side or Rear ports
  • Shafts: Straight, Splined or Tapered
  • Ports: SAE, Metric or BSPP
  • Other special features

Parameters

MT
MT Displacement Max. speed Max. Torgue Max. Output Max. Pressure Drop Max. Oil Flow
[cm3/rev] [RPM] [daNm] [kW] [bar] [Ipm]
cont. int* cont. int* cont. int* cont. int* cont. int*
MT 160 161,1 622 775 47 56 26,5 32 200 240 100 125
MT 200 201,4 620 752 59 71 33,5 40 200 240 125 150
MT 250 251,8 496 601 73 88 33,5 40 200 240 125 150
MT 315 326,3 382 461 95 114 33,5 40 200 240 125 150
MT 400 410,9 304 368 108 126 30 35 180 210 125 150
MT 500 523,6 238 289 122 137 26,5 30 160 180 125 150
MT 630 631,5 197 234 130 148 24,3 27,5 140 160 125 150
MT 725 724,3 172 209 127 147 20,2 26,8 120 140 125 150

 

* Intermitten operation: the permissible values may occur for max. 10% of every minute

Working conditions
Pressure fluid Mineral based-HLP(DIN 51524) or HM(ISO 6743/4)
Temperature range °C 40 – 140
Optimal Viscosity range (mm2/s ) 20 – 75
Filtration ISO code 20/16 (Min. recommended fluid filtration of 25 micron )

These motors have disc valve. The distributor valve has been separated from the output shaft and is driven by short cardan shaft. A balance plate counterbalances the hydraulic forces around the distributor valve. It gives the motor high efficiency even at high pressures and good starting characterstics. The Gerotor set have teeth fitted with rollers. The rollers reduce local stress and the tangential reaction forces on the rotor reducing friction to a minimum. This gives long operating life and better efficiency even at continuous high pressures.

Options

  • Flange and Wheel mount.
  • Short motor.
  • Motor with Drum Brake.
  • Tacho connection.
  • Speed sensoring
  • Side or Rear ports
  • Shafts: Straight, Splined or Tapered
  • Ports: SAE, Metric or BSPP
  • Other special features

Parameters

MS
MS Displacement Max. speed Max. Torgue Max. Output Max. Pressure Drop Max. Oil Flow
[cm3/rev][cm3/rev] [RPM] [daNm] [kW] [bar] [Ipm]
cont. int* cont. int* cont. int* cont. int* cont. int*
MS 80 80,5 810 1000 24 31 15,5 19,5 210 275 65 80
MS 100 100 750 900 30,5 39 18 22,8 210 275 75 90
MS 125 125,7 600 720 37,5 49 18 22,5 210 275 75 90
MS 160 159,7 470 560 49 60 16,5 23 210 275 75 90
MS 200 200 375 450 61 72 16,5 22 210 275 75 90
MS 250 250 300 360 72 87 14,5 18 200 250 75 90
MS 315 314,5 240 290 82,5 100 15,7 17 200 240 75 90
MS 400 397 190 230 86,5 99 11 12,5 160 190 75 90
MS 475 474,6 160 190 85 99 8,4 11,3 130 150 75 90
MS 525 522,7 145 175 85 99 7,6 10,4 115 135 75 90
MS 565 564,9 130 160 85 99 6,9 9,6 105 125 75 90

 

* Intermitten operation: the permissible values may occur for max. 10% of every minute

Working conditions
Pressure fluid Mineral based-HLP(DIN 51524) or HM(ISO 6743/4)
Temperature range °C 40 – 140
Optimal Viscosity range (mm2/s ) 20 – 75
Filtration ISO code 20/16 (Min. recommended fluid filtration of 25 micron )

These motors have spool valve. The distributor valve has been integrated with the output shaft. The Gerotor set have teeth fitted with rollers. The rollers reduce local stress and the tangential reaction forces on the rotor reducing friction to a minimum. This gives long operating life and better efficiency even at continuous high pressures.

Options

  • Flange mount.
  • Motor with needle bearing.
  • Side or Rear ports.
  • Shafts: Straight, Splined or Tapered.
  • Shaft seal for high and low pressure.
  • Ports: Metric or BSPP.
  • Speed sensoring
  • Other special features

Parameters

MR
MR Displacement Max. speed Max. Torgue Max. Output Max. Pressure Drop Max. Oil Flow
[cm3/rev] [RPM] [daNm] [kW] [bar] [Ipm]
cont. int* cont. int* cont. int* cont. int* cont. int*
MR 50 51,5 775 970 10 13 7 8,5 140 175 40 50
MR 80 80,3 750 940 20 22 12,5 15 175 200 60 75
MR 100 99,8 600 750 24 28 13 15 175 200 60 75
MR 125 125,7 475 600 30 34 12,5 14,5 175 200 60 75
MR 160 159,6 375 470 39 43 11,5 14 175 200 60 75
MR 200 199,8 300 375 38,5 46 9 12 140 175 60 75
MR 250 250,1 240 300 39 47 8 9,5 110 140 60 75
MR 315 315,7 190 240 36 47 5 8 85 115 60 75
MR 400 397 150 190 38 47 4,8 6,8 65 90 60 75

 

* Intermitten operation: the permissible values may occur for max. 10% of every minute

Working conditions
Pressure fluid Mineral based-HLP(DIN 51524) or HM(ISO 6743/4)
Temperature range °C 40 – 140
Optimal Viscosity range (mm2/s ) 20 – 75
Filtration ISO code 20/16 (Min. recommended fluid filtration of 25 micron )